Simple Plug-in Hotel Key Card Light Switch HL-E04

Price: $10.00

Product Summary

The Hotel Key Card Light Switch HL-E04 is an efficient energy-saving solution for energy conservation and electrical safety in hotel rooms. This simple plug-in switch automatically cuts power when key cards are removed from unoccupied rooms, significantly enhancing energy savings and hotel electrical safety.

One of the standout features of the HL-E04 is its versatility in activation; the switch can be operated with any standard-sized card, including bank cards, ID cards, and membership cards, not just the hotel key card. This universal functionality ensures ease of use and accessibility for various situations, though it is also worth noting as a potential security consideration since any insertable card can activate power.

Advantages of the HL-E04 include its cost-effectiveness and ease of installation, making it an attractive option for hotel owners looking to upgrade their energy management systems without significant investment.

Product Details

HL-E04 Features:

  1. Energy and Cost Efficiency: The Hotel Key Card Light Switch HL-E04 is engineered to reduce energy consumption by up to 20%, translating into significant cost savings for hotels and enhancing power safety. This efficient system ensures electricity is used only when necessary, promoting sustainable energy practices.
  2. Universal Compatibility: This switch is designed to work with any standard-sized card, offering flexibility beyond the exclusive use of hotel key cards. Guests can activate the power using bank cards, ID cards, or membership cards, providing convenience and ease of access.
  3. Automatic Operation: The HL-E04 enhances user experience by automatically cutting off the power supply when the card is removed from the switch. This feature ensures that all lights and electrical devices are turned off when guests exit the room, preventing unnecessary power usage.
  4. Affordability: Offering great value, this switch is priced competitively to fit budgetary considerations without compromising on functionality or quality.
  5. Simple Installation: Designed for quick and easy installation, the HL-E04 requires no complex wiring or batteries, making it an ideal choice for new constructions and retrofits in hotel settings.
  6. Durable and Stylish Design: The switch boasts a sleek design that complements modern hotel interiors and is built to withstand heavy usage, ensuring longevity and reliability.
  7. Integration with Existing Systems: It seamlessly integrates with existing old, outdated, mechanical, and magnetic strip hotel lock systems, allowing for a cohesive and streamlined operation across hotel security and power management systems.
  8. Customization Options: Hotels can enhance their branding with a customized logo on the switch, providing a personalized touch that aligns with the hotel’s identity and decor.

These features make the HL-E04 an excellent choice for hotels looking to enhance their energy efficiency, operational convenience, and guest experience.

Technical Details

Model HL-E04
Type Simple Plug-in Hotel Key Card Switch
Lock Size 86x86x48mm
Weight 0.40kg
Material Flame retardant PC plastic
Color White/Black
Suitable Key Card type Standard-sized cards, bank cards, ID cards, membership cards, hard paper card
Working voltage AC 180V~250V(110V required customize)c
 Electric current MAX 40A, 40A power relay
Maximum load power  8800W
Delayed power-off time 10-20 seconds
Working temperature -10℃– 60℃
Working humidity 15~85%RH

HL-E04 Installation

Step 1: Prepare the Installation Site

  • Ensure that a hole for installing the HL-E04 switch is already on the left side inside the door of your hotel room. This specific location is recommended for optimal use and accessibility.

Step 2: Install the Mounting Box (if necessary)

  • If the existing hole is not equipped with a mounting box, you may need to install one to ensure safe and secure installation. The mounting box will provide a stable enclosure for the switch.

Install the Mounting Box for Hotel Key Card Light Switch HL E05

Mounting Box

Step 3: Remove the Front Panel

  • Before proceeding with the wiring, carefully remove the front panel of the HL-E04 switch. This will expose the internal components and wiring area needed for proper installation.

Remove the Hotel Key Card Light Switch HL E05 Front Panel horz

Step 4: Connect the Wires

  • Refer to the wiring diagram provided with the switch. Connect all necessary electrical wires from your hotel room’s power supply to the appropriate terminals on the back of the switch. Ensure each connection is secure and aligned according to the diagram to ensure functionality and safety.

Simple Plug in Hotel Key Card Light Switch HL E05 Wiring Diagram

Hotel Key Card Light Switch HL-E04 Wiring Diagram

Step 5: Mount the Main Panel

  • Insert the main panel of the HL-E04 switch into the installed mounting box. Secure it in place using the provided fixing screws. Ensure the panel is firmly attached and level to prevent operational issues.

Mount the Main Panel for Hotel Key Card Light Switch HL E05

Step 6: Replace the Front Cover

  • Once the main panel is secured, reattach the switch’s front cover. Ensure that the cover is properly aligned and snaps into place to complete the installation.

Replace the Front Cover

Final Check

  • After installation, test the switch by inserting a standard-sized card to ensure it activates and deactivates the power supply as expected. This test will confirm that the switch is ready for operational use and performing correctly.

Following these steps will ensure that the HL-E04 switch is installed correctly and safely, providing a convenient and energy-efficient solution for managing room power in your hotel.

HL-E04 Troubleshooting Guide

If you’re experiencing issues with the Simple Plug-in Hotel Key Card Light Switch HL-E04, here are some common problems and their potential solutions to help you identify and resolve issues quickly:

1. Switch Does Not Activate Power

  • Check Card Type: Ensure that a standard-sized card is being used. Some cards may not fit properly or be recognized by the switch.
  • Inspect Card Insertion: Verify that the card is fully inserted into the switch. If the card is not inserted correctly, the switch might not activate.
  • Examine Power Connection: Check if the hotel room’s main power supply is switched on. Sometimes, the main power might be turned off, preventing the switch from functioning.

2. Switch Activates Power Without Card

  • Inspect for Debris: Ensure the card slot is clean and free from any debris causing a false trigger.
  • Check Internal Mechanisms: The switch’s internal mechanisms could be in trouble. If it seems to activate without a card, the sensor or internal contacts may need professional inspection.

3. Power Does Not Turn Off When the Card is Removed

  • Verify Delay Settings: Some models may have a time delay before the power cuts off after removing the card. Check the product manual for default settings or adjustable options.
  • Examine Switch Mechanisms: If there is no delay or the delay is too long, there might be a fault with the switch’s mechanism. It may not be disengaging properly when the card is removed.

4. Loose or Inconsistent Power Connection

  • Check Mounting and Installation: Ensure that the switch is securely mounted and that all screws and fittings are tight. A loose switch can lead to inconsistent connectivity.
  • Inspect Wiring Connections: Loose or improperly connected wires can cause intermittent power issues. Turn off the power at the main circuit breaker before inspecting and securing loose connections.

5. Switch Does Not Fit Properly in the Mounting Box

  • Review Installation: Ensure the mounting box is suitable for the HL-E04 switch. If the switch does not fit properly, it may require a different mounting box or adjustments to the existing installation.

6. Physical Damage

  • Visual Inspection: Check for any visible signs of damage like cracks, burns, or melted components. Physical damage can impair function and typically requires the switch’s replacement.

If these troubleshooting steps do not resolve the issue, it might be necessary to consult with a professional electrician or contact customer support for further assistance. Always ensure that any inspections or repairs are conducted safely, with the power turned off, to prevent electrical hazards.

FAQs About Hotel Key Card Light Switch HL-E04

Yes, the HL-E04 can be activated with any card that fits into the slot, including bank cards, ID cards, and membership cards, not just the hotel’s key card. This feature provides flexibility and convenience for guests but should be managed with consideration to security.

The main benefits include energy savings, as the switch cuts off power when the room is unoccupied, reducing unnecessary power consumption. It also enhances safety by minimizing the risk of electrical hazards from unattended appliances.

Yes, there is an option to customize the switch with the hotel’s logo or other branding elements, providing a personalized touch and reinforcing brand identity within the hotel room.

While the HL-E05’s universal functionality offers convenience, it also presents a potential security risk, as any card can activate the room’s power. Hotels may want to consider additional security measures or protocols to address this concern.

Yes, the switch is compatible with existing hotel systems such as old and outdated temic hotel lock systems, magnetic strip hotel lock systems, and mechanical card hotel lock systems, allowing for a cohesive and streamlined operation across hotel security and power management systems.

If you have any questions, please feel free to leave your questions by using the form below!

Customer Questions
© Copyright 2012 - 2024 Dongguan Yangyuan Technology Co.,Ltd.