Mifare RFID Hotel Key Card Power Switch HL-E01

Price: $11.00-$14.00

Product Summary

The Mifare RFID Hotel Key Card Power Switch HL-E01 is a specialized energy-saving switch that works seamlessly with Mifare hotel lock systems. This switch requires a Mifare RFID 13.56 MHz key card to activate the power supply in hotel rooms, ensuring electricity is used efficiently and only when necessary.

This switch activates the power supply in hotel rooms only when a Mifare RFID 13.56 MHz key card is inserted, promoting efficient energy use and ensuring electricity is utilized only when needed. Once the card is removed, the switch automatically cuts off the power after a brief delay of about 15 seconds.

The HL-E01 is highly compatible with most existing MIFARE RFID hotel lock systems, making it a seamless, energy-efficient upgrade for modern hotels.

This switch is ideal for hotels looking to improve their energy management and safety protocols while maintaining compatibility with existing MIFARE systems.

Product Details

HL-E01 Features:

The hotel room key card power switch HL-E01 is specifically engineered for MIFARE hotel locking systems, offering a smart solution for energy management and safety in hotel environments. Here’s a detailed look at its key features:

  • Energy Efficiency: Capable of saving up to 40% in energy and related costs, this switch encourages substantial energy conservation, directly impacting the hotel’s operational expenses positively.
  • Enhanced Safety: Designed to enhance the electrical safety of hotel rooms, the switch automatically cuts off the power supply once the MIFARE RFID key card is removed, ensuring all electrical devices are safely deactivated when not in use.
  • Exclusive Compatibility: Operates exclusively with MIFARE RFID cards, ensuring seamless integration with specialized security systems and preventing unauthorized use.
  • Ease of Use: Guests can insert their MIFARE key card to activate the room’s power, making it straightforward and user-friendly. The power is automatically disconnected when the card is removed, which is convenient and energy-efficient.
  • Simple Installation: The switch is designed for easy installation with no complex wiring or batteries required, allowing for quick setup in any hotel room.
  • Durable Design: Features a sleek, robust design engineered to withstand heavy use, making it suitable for high-traffic hotels.
  • System Integration: Perfectly integrates with existing MifARE hotel lock systems, creating a cohesive and efficient operational system.
  • Customization: This option allows you to customize with a hotel’s logo, aligning with brand identity and enhancing the aesthetic appeal of hotel interiors.

These features make the HL-E01 a practical and effective choice for modern hotels looking to improve energy efficiency, ensure safety, and maintain consistent branding through sophisticated technology.

Technical Details

Model HL-E01
Type Mifare RFID Hotel Key Card Switch
Lock Size 86x86x48mm
Weight 0.40kg
Material Flame retardant PC plastic
Color White/Black/Gold
Suitable Key Card type Mifare 13.56Mhz RFID card
Working voltage AC 180V~250V(110V required customize)
 Electric current MAX 40A, 40A power relay
Maximum load power  8800W
Delayed power-off time 10-20 seconds
Working temperature -10℃– 60℃
Working humidity 15~85%RH

HL-E01 Installation Guide

Preparation:

  1. Ensure Power is Off: Turn off the main power supply to avoid electrical hazards before installing.

Installation Steps:

  1. Prepare the Installation Site: Confirm that a hole has been properly prepared on the side of the room door where the switch will be installed. This will accommodate the switch and its components.
  2. Mounting Box Installation (If Necessary): Use a switch mounting box to assist with the installation. This box will help ensure the switch is installed smoothly and safely. Mount the box in the prepared hole and secure it with screws. Mounting Box Installation for Hotel Key Card Power Switch HL E001
  3. Remove the Front Panel: Carefully remove the front panel of the HL-E01 switch. This will separate the front panel from the main panel, allowing access to the internal components for wiring. Remove the Front Panel 1 horz
  4. Wire the Main Panel: Connect the electrical wires from the room’s devices to the appropriate terminals on the switch according to the wiring diagram provided. Ensure that all connections are secure and correct. Hotel Key Card Power Switch HL E001 wiring diagram
  5. Install the Main Panel: Place the main panel of the switch into the mounting box. Secure it using the screws provided to ensure it is firmly in place. Install the Main Panel
  6. Reattach the Front Panel: Once the main panel is securely installed, replace the front panel to cover the internal components and complete the installation. Reattach the Front Panel

Important Notes:

  • Avoid Wire Damage: Be careful not to pinch any wires against the relay on the back of the switch during installation, as this can prevent the switch from cutting off power correctly.
  • Check Wiring if Power Supplies Without Card: If the switch provides power without a Mifare card inserted, check and ensure all wiring connections are correct and reinstall them if necessary.
  • Remove the Card After Testing: Always remove the card after installation testing to avoid dust accumulation in the card slot if the power is turned off.
  • Consider an AC Contactor: You should purchase an AC contactor separately to protect the switch from potential damage due to high current loads.

Safety Tips: Always ensure that electrical installations are performed by qualified personnel and adhere to local electrical codes and standards. This guide will help ensure a safe and effective Mifare RFID Hotel Key Card Power Switch HL-E01 installation.

HL-E01 Troubleshooting Guide

If you encounter issues with the Mifare RFID Hotel Key Card Power Switch HL-E01, here are some common problems and their possible solutions:

1. Switch Does Not Activate Power

  • Check Power Supply: Ensure that the main power to the room is turned on.
  • Inspect Card: Verify that the MIFARE RFID card is compatible and functioning correctly. If possible, test with another card.
  • Review Installation: Double-check that the wiring connections match the provided wiring diagram. Loose or incorrect wiring can prevent the switch from functioning.

2. Power Does Not Turn Off When the Card is Removed

  • Delay Feature: Remember that the switch has a built-in delay of about 15 seconds after removing the card before power is cut off. Wait to see if the power turns off after this period.
  • Check Mechanism: If power continues beyond this delay, ensure that the switch mechanism is not stuck and that there is no debris in the card slot.

3. Power Activates Without Inserting Card

  • Inspect for Short Circuits: Check for any short circuits in the wiring that bypass the switch’s control mechanism.
  • Examine Card Slot: Ensure the card slot is clear of any objects or debris that could be triggering the switch.

4. Frequent Power Interruptions

  • Check Connections: Ensure all wire connections are secure and not loose, which can cause intermittent power issues.
  • Examine Card and Reader: Make sure the MIFARE RFID card is not damaged and that the card reader on the switch is clean and functioning properly.

5. Switch Shows Physical Signs of Damage

  • Physical Inspection: Look for any visible signs of damage, such as cracks, burns, or melted components. Damaged components will likely require replacement.
  • Safety First: If significant damage occurs, consider replacing the entire unit to ensure safety and functionality.

6. Incorrect Installation Symptoms

  • Revisit Installation Guide: Review the installation steps to ensure everything was completed correctly according to the manufacturer’s guidelines.
  • Professional Help: If problems persist, consult a professional electrician or seek support from the manufacturer. might be necessary

If none of the above solutions resolve the issue, it may be best to contact the manufacturer or a professional technician for further diagnosis and assistance. Always ensure safety by turning off the power at the main breaker during any inspection or maintenance work.

FAQs About Hotel Key Card Power Switch HL-E01

The Mifare RFID Hotel Key Card Power Switch HL-E01, which utilizes MIFARE technology, is generally more secure against hacking than basic RFID systems due to enhanced encryption and security protocols.

But please note that almost all Mifare RFID 13.56Mhz cards bypass hotel key card power switch HL-E01!

However, like any electronic system, it is not completely immune to hacking, especially if security vulnerabilities exist or attackers gain physical access. Continuous updates and proper security practices are essential to minimize the risk.

The HL-E01 is designed exclusively for MIFARE RFID cards operating at 13.56 MHz. It will not recognize or work with any other types of RFID cards or magnetic stripe cards.

The HL-E01 helps reduce energy consumption by activating the power only when a valid MIFARE RFID card is inserted into the switch. This ensures that electricity is used only when the room is occupied. Additionally, the switch automatically cuts off power around 15 seconds after the card is removed, which helps prevent unnecessary energy usage when rooms are unoccupied.

The HL-E01 is specifically designed to integrate seamlessly with MIFARE RFID hotel lock systems. It might not be compatible with other locking systems that do not use MIFARE technology.

Yes, the HL-E01 offers customization options, including the ability to add a hotel’s logo on the switch. This helps maintain brand consistency throughout the hotel.

The HL-E01 requires minimal maintenance. Regular cleaning of the card slot to remove dust and debris is recommended to ensure optimal functionality. Also, periodic checks of the electrical connections and mounting can help maintain its performance and safety.

If you have any questions, please feel free to leave your questions by using the form below!

Customer Questions
© Copyright 2012 - 2024 Dongguan Yangyuan Technology Co.,Ltd.